ME.TRU-10.391…-2

INDUSTRIAL TRANSFORMER TECHNIQUE Copyright © 2009-2013.


 

    TYPE: ME.TRU-10   10VA

        CORE SIZE: UI39/8

 

                   Features     

 - Epoxy resin cast

 - Two chambers bobbin

 - Insultation primary-secondary: 4KV.

 - Increased humidity resistance

 

Manufacturing standard EN 61558 

 - Safety insultation transformer

 - Max.ambient temperature: ta 700C

 - Insultation class:ta70°/ B 1300C

 - Double insultated

 - Degree of protection: IP00

 - Not short-circuited

  





      Application

     -PCB mounting installation

     -Low height design

     -Possibility of serial and parallel connection of primary and secondary coils

 

     Deviation of secondary voltages  5%

    Prescribed primary circuit fuse 80mAT

 

      Modell numer

Primary             Pin

voltage              configuration

Secondary       Pin

voltage            configuratuion

 Secondary

 current

ME.TRU-10.39106-2

     2×115 V

     1-4    6-9

      2×6 V

   11-15   16-20

   2×0,83 A

ME.TRU-10.39175-2

     2×115 V

     1-4    6-9

      2×7,5 V

   11-15   16-20

   2×0,66 A

ME.TRU-10.39109-2

     2×115 V

     1-4    6-9

      2×9 V

   11-15   16-20

   2×0,55 A

ME.TRU-10.39112-2

     2×115 V

     1-4    6-9

      2×12 V

   11-15   16-20

   2×0,41 A

ME.TRU-10.391135-2

     2×115 V

     1-4    6-9

      2×13,5 V

   11-15   16-20

   2×0,37 A

ME.TRU-10.39115-2

     2×115 V

     1-4    6-9

      2×15 V

   11-15   16-20

   2×0,33 A

ME.TRU-10.39118-2

     2×115 V

     1-4    6-9

      2×18 V

   11-15   16-20

   2×0,27 A

ME.TRU-10.39124-2 *

     2×115 V

     1-4    6-9

      2×24 V

   11-15   16-20

   2×0,20 A

  *Certified as insulation transformer

  Click on the icon to view the data sheet in PDF format.