ME.TRU-10.391…-2
TYPE: ME.TRU-10 10VA CORE SIZE: UI39/8
Features - Epoxy resin cast - Two chambers bobbin - Insultation primary-secondary: 4KV. - Increased humidity resistance
Manufacturing standard EN 61558 - Safety insultation transformer - Max.ambient temperature: ta 700C - Insultation class:ta70°/ B 1300C - Double insultated - Degree of protection: IP00 - Not short-circuited
|
Application
-PCB mounting installation
-Low height design
-Possibility of serial and parallel connection of primary and secondary coils
Deviation of secondary voltages 5%
Prescribed primary circuit fuse 80mAT
Modell numer |
Primary Pin voltage configuration |
Secondary Pin voltage configuratuion |
Secondary current |
||
ME.TRU-10.39106-2 |
2×115 V |
1-4 6-9 |
2×6 V |
11-15 16-20 |
2×0,83 A |
ME.TRU-10.39175-2 |
2×115 V |
1-4 6-9 |
2×7,5 V |
11-15 16-20 |
2×0,66 A |
ME.TRU-10.39109-2 |
2×115 V |
1-4 6-9 |
2×9 V |
11-15 16-20 |
2×0,55 A |
ME.TRU-10.39112-2 |
2×115 V |
1-4 6-9 |
2×12 V |
11-15 16-20 |
2×0,41 A |
ME.TRU-10.391135-2 |
2×115 V |
1-4 6-9 |
2×13,5 V |
11-15 16-20 |
2×0,37 A |
ME.TRU-10.39115-2 |
2×115 V |
1-4 6-9 |
2×15 V |
11-15 16-20 |
2×0,33 A |
ME.TRU-10.39118-2 |
2×115 V |
1-4 6-9 |
2×18 V |
11-15 16-20 |
2×0,27 A |
ME.TRU-10.39124-2 * |
2×115 V |
1-4 6-9 |
2×24 V |
11-15 16-20 |
2×0,20 A |
*Certified as
insulation transformer
Return to previous page