ME.TRU-14.392…-2

INDUSTRIAL TRANSFORMER TECHNIQUE Copyright © 2009-2013.


 

    TYPE: ME.TRU-14   14VA

        CORE SIZE: UI39/10,2

 

                   Features     

 - Epoxy resin cast

 - Two chambers bobbin

 - Insultation primary-secondary: 4KV.

 - Increased humidity resistance

 

Manufacturing standard EN 61558 

 - Safety insultation transformer

 - Max.ambient temperature: ta 700C

 - Insultation class:ta70°/ B 1300C

 - Double insultated

 - Degree of protection: IP00

 - Not short-circuited

 

 







      Application

     -PCB mounting installation

     -Low height design

     -Possibility of serial and parallel connection of primary and secondary coils

 

    Deviation of secondary voltages  5%

   Prescribed primary circuit fuse 100mAT

 

      Modell numer

Primary             Pin

voltage              configuration

Secondary       Pin

voltage            configuratuion

 Secondary

 current

ME.TRU-14.39206-2

    2×115 V

     1-4    6-9

      2×6 V

   11-15   16-20

    2×1,16 A

ME.TRU-14.39275-2

    2×115 V

     1-4    6-9

      2×7,5 V

   11-15   16-20

    2×0,93 A

ME.TRU-14.39209-2

    2×115 V

     1-4    6-9

      2×9 V

   11-15   16-20

    2×0,77 A

ME.TRU-14.39212-2

    2×115 V

     1-4    6-9

      2×12 V

   11-15   16-20

    2×0,58 A

ME.TRU-14.392135-2

    2×115 V

     1-4    6-9

      2×13,5 V

   11-15   16-20

    2×0,51 A

ME.TRU-14.39215-2

    2×115 V

     1-4    6-9

      2×15 V

   11-15   16-20

    2×0,46 A

ME.TRU-14.39218-2

    2×115 V

     1-4    6-9

      2×18 V

   11-15   16-20

    2×0,38 A

ME.TRU-14.39224-2 *

    2×115 V

     1-4    6-9

      2×24 V

   11-15   16-20

    2×0,29 A

  *Certified as insulation transformer

  Click on the icon to view the data sheet in PDF format.